Contribuţii la perfecţionarea şi evaluarea aparatelor de ventilaţie pulmonară

Ciurea, Bogdan Marius
2012-10-17

Abstract: UNIVERSITY „POLITEHNICA” OF BUCHAREST FACULTY OF MECHANICAL ENGINEERING AND MECHATRONICS DEPARTMENT OF MECHATRONICS AND PRECISION MECHANICS Doctoral dissertation title: ”Contributions to the improvement and evaluation of pulmonary ventilation” PhD supervizor: Prof. Dr. eng. Doru Dumitru PALADE PhD student: eng. Bogdan Marius CIUREA Abstract This PhD thesis deals, with the theoretical and experimental, testing of lung ventilators. In this thesis, after analyzing pneumatic diagrams from multiple devices, it’s been developed a general pneumatic block diagram of the ventilator, valid for any manufacturing company or medical area it serves. Each unit is presented with its functional role and constructive representative variants. Current test methods are shown focusing on what needs to be improved. Is conceived and developed a unitary testing system that can test lung ventilators in terms of ventilation parameters, patient blocks, nebulizer, and for anesthesia also the anesthetic vaporizer. The unitary testing system consists of testing system for ventilation parameters and testing system of the patient blocks. In the execution of the system were designed and built electronic control module, a sensor for determining flow direction of the gas, and systems for sensor and valves calibration. In developing the system, which is based on a data acquisition and control system, it was aimed to eliminate human error in the testing process, verify the ventilators function with the patient connected to a artificial breathing machine, automatic generation of system test report, determining all ventilation parameters. For the system command it’s been developed a program in LabView environment. With the unitary testing system experimental determinations were performed on multiple devices, both functional and defect, in order to follow the system reaction in multiple situations. After analyzing the experimental results it is observed that the testing system is functional and provides solutions for testing equipment used for long periods. Utilization of this equipment increases productivity and significantly decrease the amount of equipment required to be transferred to the testing site.

Keyword(s): Echipament medical -- Teză de doctorat ; Ventilaţie artificială -- Teză de doctorat ; Aparatură medicală -- Teză de doctorat
OPAC: See record in BC-UPB Web OPAC
Full Text: see files

Record created 2017-03-08, last modified 2017-03-08

Similar records


 
People who viewed this page also viewed:
(242)  Optimizarea conceptuală şi operaţională a instalaţiilor chimice multiscop - Voinescu, Sorin - ROMDOC-BC_UPB-THESIS-2003-000000054
(233)  Managementul congestiilor în sistemele electroenergetice în prezenţa surselor regenerabile - Boambă, Claudia-Elena - ROMDOC-THESIS-2021-2325
(231)  Tehnologiile informării şi comunicării : suport de curs - Curta, Olimpia - ROMDOC-BOOK-2007-005
(231)  Contribuţii la iniţierea şi dezvoltarea de tehnologii suport pentru activităţi de testare şi mentenanţă echipamente şi circuite hidraulice aferente - Gyöngyöşi, Tiberiu - ROMDOC-THESIS-2021-2296
(230)  Cercetări asupra managementului energetic al autovehiculelor de teren - Irimia, Petru-Cristinel - ROMDOC-THESIS-2021-2315

 
Rate this document:
Be the first to review this document.


Discuss this document:
Start a discussion about any aspect of this document.