Format: HTML | BibTeX | DC | EndNote | NLM | MARC | Journal | MARCXML
Thesis / ROMDOC-THESIS-2017-1176

Diagnoza motoarelor asincrone şi a transformatoarelor de putere folosind transformatele de semnal wavelet şi Stockwell

Media, Marius
2012-12-07

Abstract: Abstract Motoarele asincrone trifazate rotative şi transformatoarele electrice trifazate de putere sunt unele din componentele cele mai importante în ceea ce priveşte securitatea instalaţiilor din domeniul industrial, şi sistemele de alimentare cu energie. Un procent important din totalul motoarelor asincrone rotative şi al transformatoarelor de putere din industrie sunt din generaţia anilor 1980. La acea vreme sistemele de diagnoza nu erau implementate în faza de proiectare a acestor echipamente electromecanice de acţionare şi de alimentare cu energie. În această lucrare a fost urmărită elaborarea de tehnici şi metode de diagnoză uşor de implementat şi la costuri minime. Diagnoza defectelor bazată pe analiza curentului absorbit din reţea este o metodă neinvazivă, se poate realiza de la distanţă, on-line, cu costuri minime. Detecţia defectelor incipiente minore este importantă pentru sistemele de acţionare cu motoare asincrone şi pentru transformatoarele electrice, pentru a preveni consecinţele defectelor grave, ce implică costuri mari de reparaţie şi revizii, pierderi economice datorită stagnării producţiei, afectarea personalului de exploatare şi a mediului înconjurător şi afectarea securităţii nucleare în cazul centralelor nucleare. Studiul a fost concentrat pe diagnoza tehnică a defectelor de natură electrică ale motoarelor asincrone şi transformatoarelor electrice pe baza analizei curentului absorbit din reţea. Modelul motorului asincron rotativ traifazat în coordonate dq şi ABC/abc realizat în Matlab/Simulink, a fost utilizat pentru studiul defectelor electrice statorice şi rotorice şi defectelor de alimentare. Modelul transformatorului electric realizat în Matlab/Simulink şi PSCAD a fost utilizat pentru studiul defectelor electrice ale înfăşurărilor primare şi secundare. Vectorul Park diferenţial, şi fazorul spaţial al curentului instantaneu al motorului, au fost folosiţi ca instrumente de diagnoză a defectelor motorului asincron trifazat. De asemenea, analiza semnalului vitezei unghiulare a motorului asincron. Analiza cu transformatele de semnal în timp-frecvenţă Wavelet şi Stockwell a curentului absorbit la pornire a fost utilizată pentru diagnoza defectelor de natură electrică ale motoarelor asincrone şi transformatoarelor electrice. The rotary three-phase induction motors and three-phase power transformers are some of the most important components in the security of industrial plants and power supply systems. A significant percentage of all rotary motors and power transformers in the industry are of the 1980’s generation. At that time diagnostic systems were not implemented in the design phase of these power supply and drives electromechanical equipments. In this paper was pursued the development of diagnostic techniques and methods easy to implement and lower costs. The fault diagnosis based by supply current analysis is a noninvasive method, can be achieved remotely, on-line, with minimal costs. The minor defects early detection is important for drives with induction motors and for power transformers to prevent serious defects consequences, involving the high cost of repair and overhaul, economic losses due to stagnation of production, affecting of the operating personnel and environment and impairment of nuclear safety for nuclear power plants. Study was focused on technical diagnosis and prognosis of their electrical faults such as the analysis of the line current. The study was focused on technical diagnosis of electrical faults from induction motors and power transformers based on the analysis of the supply current. The Matlab/Simulink model of rotary three-phase induction motor in dq and ABC/abc coordinate was used to study of stator and rotor electrical faults and supply faults. The Matlab/Simulink and PSCAD model of power transformer was used to study of primary and secondary windings electrical faults. The differential Park's vector, and motor instantaneous current space phasor, was used as tools for three-phase motor faults diagnosis. Also, the induction motor angular speed signal analysis. The analysis with Stockwell and Wavelet time-frequency signal transforms of the stator current absorbed at start-up, was used for faults diagnosis of induction motors and power transformers.

Keyword(s): Diagnoză tehnică -- Metode -- Teză de doctorat ; Motor asincron -- Diagnoză tehnică -- Teză de doctorat Transformatoare de putere -- Diagnoză tehnică -- Teză de doctorat ; Transformata Wavelet -- Teză de doctorat ; Transformata Stockwell -- Teză de doctorat
OPAC: See record in BC-UPB Web OPAC
Full Text: see files

Record created 2017-03-31, last modified 2017-03-31

Similar records


 
People who viewed this page also viewed:
(256)  Optimizarea conceptuală şi operaţională a instalaţiilor chimice multiscop - Voinescu, Sorin - ROMDOC-BC_UPB-THESIS-2003-000000054
(254)  Tehnologiile informării şi comunicării : suport de curs - Curta, Olimpia - ROMDOC-BOOK-2007-005
(244)  Managementul congestiilor în sistemele electroenergetice în prezenţa surselor regenerabile - Boambă, Claudia-Elena - ROMDOC-THESIS-2021-2325
(242)  Cercetări privind monitorizarea, diagnosticarea şi modelarea generatoarelor sincrone din centralele electrice - Catrinoiu, Mircea - ROMDOC-THESIS-2017-1371
(242)  Scientific Bulletin Series C:Electrical engineering - ROMDOC-Journal-2007-003

 
Rate this document:
Be the first to review this document.


Discuss this document:
Start a discussion about any aspect of this document.